Description
The system consists of a precipitation tank supplied with water by a submersible pump. The clean water from the precipitation tanks runs over to the clean water tank and by a system of pumps is supplied to the factory (clean water tank and pumps are not supplied). The sludge is dehydrated in a filter press which is installed on the main structure of the system.
Under the picture you can take a look to its Technical Characteristics.
N.1
|
PRECIPITATION TANKS
|
|||
|
Two precipitation tanks are combined in the main structure of the system
|
|||
|
· Total capacity
|
12.000
|
lit
|
|
|
· Length
|
2,1
|
m
|
|
|
· Width
|
2,1
|
m
|
|
|
· Height
|
5,5
|
m
|
|
N.1
|
Automatic valve for the discharge of the sludge
|
Φ100
|
mm
|
|
N.1
|
Manual valve for the discharge of the sludge
|
Φ100
|
mm
|
|
N.1
|
SUBMERSIBLE PUMP
|
|||
|
Supply
|
750
|
lit/ min
|
|
|
Useful supply height
|
10
|
m
|
|
|
Motor power
|
3.5
|
HP
|
|
N.1
|
Level control for pump working
|
|||
N.1
|
PREPARATION DILUTION TANK
|
|||
|
Constructed by carbonous steel special treaded and painted with anti-erosion paint both side
|
|||
|
Capacity
|
1000
|
Lit
|
|
N.1
|
DOSING PUMPS
|
|||
|
Supply
|
52
|
lit/h
|
|
|
Useful supply height
|
5
|
m
|
|
|
Motor power
|
0,37
|
KW
|
|
Ν.1
|
SLUDGE MIXER TANK
|
|||
|
Constructed by carbonous steel special treaded and painted with anti-erosion paint both side
|
|||
|
Capacity
|
700
|
Lit
|
|
N.1
|
Mixer motor
|
1
|
HP
|
|
N.1
|
Manual valve for the discharge of the sludge
|
|||
N.1
|
Level control
|
|||
N.1
|
FILTER PRESS FP 400/7 INT
|
|||
|
Complete hydraulic unit
|
|||
|
Dimension
|
0.4×0.4
|
m
|
|
|
Hydraulic pump
|
4
|
Kw
|
|
|
Sludge production per cycle
|
32
|
dm3
|
|
N.1
|
Air movable sludge pump with double membrane
|
|||
|
Sludge supply
|
12
|
M3/h
|
|
|
Pressure supply
|
6
|
Bar
|
|
N.1
|
ELECTRICAL BOARD
|
|||
|
Full electrical board with PLC for the control of the complete system
|
|||
|
Included
|
|||
|
· Cables for the connection of the parts of the systems
|
|||
|
· Additional installation parts
|
|||
|
Not included power supply cables for the systems
|
Reviews